Abstract

In this investigation, the development of an empirical relationship to determine the porosity and microhardness of the coatings through low-pressure cold-sprayed (LPCS) aluminum alloy/alumina metal matrix composite (MMC) deposit. Spray parameters like temperature, standoff distance (SOD), and powder feed rate play an essential part in the determination of the coating effectiveness. In this study, 3 variables, 5 levels of central composite rotatable design (CCD) were used to decrease the total count of the experimentation. A mathematical model has been developed to evaluate the porosity and hardness of the coated samples along with LPCS spray parameters, and the model’s applicability was inspected by ANOVA. Utilizing response surface methodology, spray parameter optimization was carried out. The deposit developed by optimal spray parameters produces the lowest surface porosity of 3.31 vol.% and a higher hardness of 137.21 HV compared with other coated samples. It is validated through the response graph. As a result, the optimized parameters for aluminum alloy/alumina metal matrix composite (MMC) coatings via LPCS are 500 degrees Celsius, 10 mm SOD, and 20 grams/min powder feed rate.