Abstract
This study quantifies the range of premixed flame conditions for which CH fluorescece diagnostics are applicable, and it shows that the CH fluorescence signal can be increased if some of the hydrocarbon fuel is replaced with hydrogen. The CH fluorescence signal is found to be adequate for fuel-air equivalence ratios (phi) as small as 0.85 for both methane-air and propane-air flames. The CH signal increases until a maximum at phi = 1.25 and phi = 1.35 for methane-air and propane-air flames, respectively, and then decreases for richer conditions. A strategy to increase the CH fluorescence signal and decrease interference from soot precursors is proposed by addition of the proper amount of hydrogen to the hydrocarbon fuel. Hydrogen addition reduces the background signal from soot precursors by as much as afactor of 10 and increases the CH fluorescence signal by as much as 80%. The normalized CH fluorescence measurements are compared with computations that utilize GRI-MECH 3.0 chemistry. Sources experimental uncertainties are discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.