Abstract

AbstractThe fuel cell system (FCS) is commonly combined with an energy storage system (ESS) for enhancing the performance of the ship. Consequently, the battery ESS size and power allocation strategy are critical for the hybrid energy system. This paper focuses on designing a method to solve these two problems. First, a battery degradation model is employed to assess the ESS lifetime. Subsequently, the sizing problem and the optimal power allocation are integrated into a cost‐minimization problem, which is solved by a double‐loop optimization approach. The inside loop utilizes the battery degradation model to calculate ESS lifetime. In the outside loop, a power allocation strategy based on the hybrid Particle Swarm Optimization algorithm and Gray Wolf Optimization algorithm is presented. Finally, the power allocation strategy is extended to real‐time implementation by the equivalent consumption minimization strategy (ECMS) and an improved ECMS is proposed to make the FCS operates near the maximal efficiency point. Compared with ECMS, the operating cost reduces by 0.26%. The result indicates that the proposed method can optimize the ESS size efficiently, and the power allocation strategy can assure the stable operation of the fuel cell ship.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call