Abstract
This paper describes the configuration of a permanent magnet linear actuator for biometric applications and explains the basics of the methodology used to evaluate the actuator thrust. The methodology, based on analytical expressions of the magnet flux linkage, enables a fast and accurate evaluation of the axial force and can apply to any set of coaxial coils. The formulations are used to optimize the actuator configuration, in order to improve the thrust uniformity along the mover stroke, some technological design fulfilling some technological design constraints. Introducing an auxiliary set of coaxial coils, the optimization procedure enables a remarkable uniformity improvement. The results are verified by finite-element analyses, and the measurements performed on a prototype confirm the effectiveness of the design procedure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.