Abstract

This study is focused on the optimization of a sensible thermal storage system subjected to a cyclic energy source. The objective is to minimize the system heat storage mass and its geometry to guarantee its operation within an admissible temperature range. The storage medium is modeled as a Lumped system and the working fluid by a non-capacitive energy balance. The storage medium is composed of an array of parallel flat plates submitted to an air stream. The optimization is based on an exhaustive search method. It is observed that the minimum heat storage mass is proportional to the mass airflow rate. An optimal relationship between the superficial heat transfer rate and the fluid flow inertia, given by the dimensionless parameter NTU, is found to be constant (4.03) and independent in respect to the mass flow rate. The system time constant was invariable (3,230 s) for the optimal relationship between the interface heat transfer rate and the system inertia.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.