Abstract

A MOS–IGBT–SCR component that was proposed in a previous paper to increase the device robustness and the cost of ESD protection circuit is optimized in this paper. In order to improve its latch-up immunity, several variations of geometrical parameters that have been simulated using TCAD Sentaurus Device in another previous paper have been implemented and compared in this work. The drift area, the form factor, and the proportion of P+ sections inserted into the drain are the main parameters, which have a significant impact on the latch-up immunity. TLP characterization, and curve tracer measurements have been carried out to evaluate the proposed solution. Holding current increases up to 70mA and holding voltage up to 10V.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.