Abstract

Fluoxetine is the most prescribed drug for treatment of depression. Recently, its presence in aquatic environment has been receiving a growing interest as several studies assessed its effects on aquatic fauna. Therefore, it's important to have an analytical method capable of monitoring these compounds at low concentrations. In this study, a new method was developed based on dispersive liquid-liquid microextraction to preconcentrate fluoxetine in a small volume of water sample (6mL) before chromatographic analysis using ultra high performance liquid chromatography with fluorescence detection. Effect of composition and volume of extracting mixture, sample pH, vortexing time and salt addition were evaluated. Optimization of extraction conditions lead to an enrichment factor of 61±18. After extraction optimization, recovery percentages of fluoxetine spiked into different water matrices between 83-110% were obtained. For the optimized method, the calibration curve was obtained in the range of 160-2500ng/L with a limit of detection of 98.9ng/L and a limit of quantification of 329.8ng/L.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.