Abstract
The four-switch buck-boost (FSBB) converter usually adopts a pseudo-continuous conduction mode (PCCM) soft switching (ZVS) control strategy, but there is a problem with the low efficiency of FSBB converters under light loads. Firstly, the constraints that the control variables of the FSBB converter need to satisfy are analyzed, and it is pointed out that the fixed frequency constraint is not necessary. Then, the switching frequency is used to control the degree of freedom, and the quantitative relationship between the FSBB converter loss and the switching frequency is obtained. Finally, for different input voltages and loads, the switching frequency corresponding to the minimum power loss is calculated offline. By optimizing the switching frequency, the light-load efficiency of the FSBB converter is improved. A prototype with an input voltage range of 210 V–330 V, an output voltage of 270 V, and an output power of 3 kW was developed. The loss was reduced by 15% at 20% load, and the peak efficiency of the converter reached 99.23%. The experimental results verified the effectiveness of the proposed control strategy.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.