Abstract

A simple, selective, sensitive, accurate, and precise method was developed for determination of metformin hydrochloride (MF) in human urine using RP-HPLC. The method depends upon using an octylsilyl (C8) 5 microm particle size column at ambient temperature with mobile phase consisting of 33 mM sodium dihydrogen phosphate containing 6.38 mM hexanesulfonic acid sodium salt and adjusted to apparent pH 3.0 with phosphoric acid-acetonitrile (93 + 7, v/v) at a flow rate of 1.5 mL/min. Quantitation was achieved with UV detection at 231 nm based on peak area with a linear calibration curve over the concentration range of 0.01-50 microg/mL. The proposed method was applied to the determination of the urinary excretion pattern of MF (the cumulative amounts excreted were calculated without pretreatment of the urine sample) and for determination of the dissolution pattern of MF tablets. The proposed method was completely validated according to the U.S. Food and Drug Administration guidelines.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.