Abstract

In this study, two practical dual-tuned birdcage configurations for quantitative assessment of articular cartilage with sodium magnetic resonance imaging (MRI) were designed and compared. Two 1.5 T dual-tuned birdcages, a four-ring birdcage (FRB) and an alternating rungs birdcage (ARB), were built and then characterized by bench and MRI measurements. The relative uniformity (RU) and the efficiency of the coils were compared using (23)Na and (1)H B1 maps. In vivo images of a volunteer were acquired. Bench measurements showed matching and decoupling coefficients of the quadrature channels lower than -20 dB. The RUs and 180° pulse amplitudes of the FRB/ARB were determined as: (1)H RU =94.4/74.4%, (23)Na RU =95.2/93.6%, (1)H 180° pulse amplitude =69.2/75.4 V and (23)Na 180° pulse amplitude =45.1/45.9 V. The in vivo (23)Na images acquired with the FRB show a signal-to-noise ratio (SNR) of 6 to 14 in the cartilage. Due to its superior (1)H homogeneity and efficiency and its slightly better (23)Na homogeneity, the FRB is the overall preferred coil for the given requirements of this study. The achieved in vivo SNR is adequate for quantitative (23)Na and high resolution (1)H imaging.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call