Abstract
Natural-abundance phosphomolybdic acid (H3(Mo12PO40) ‧12H2O, 0.181–0.552 g Mo/mL) solutions were irradiated with 12.9 MeV protons on a GE PETtrace cyclotron using an adapted standard liquid target. Technetium-94m (94mTc) was produced through the 94Mo(p,n)94mTc nuclear reaction with saturation yields of up to 53 ± 6 MBq/μA. End of bombardment activities of 161 ± 17 MBq and 157 ± 7 MBq were achieved for the 0.552 g Mo/mL solution (10 μA for 30 min) and 0.181 g Mo/mL solution (15 μA for 60 min), respectively. No visible degradation of the niobium target body and foil were seen during the irradiations of up to 15 μA for 60 min. The produced 94mTc was separated from the target phosphomolybdic acid solution with >98% recovery using an aqueous biphasic extraction resin. Compared to previous reported liquid target methods for 94mTc production, the better production yield, in-target solution stability during irradiation and 94mTc separation recovery of phosphomolybdic acid makes it a very promising target material for routine clinical 94mTc production at medical facilities with liquid targets already installed for 18F production.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.