Abstract

The aim of this study was to create a simple, solventless technique without derivatisation in order to analyze a broad range of volatiles in beer wort. A method was developed using headspace solid-phase microextraction coupled with gas chromatography and mass spectrometry. The procedure was optimised by selection of the appropriate fibre and optimisation of extraction temperature, extraction time, and salting-out. The detection limits were well below the actual wort concentrations of the selected volatiles, ranging from 12 ng/l for linalool to 0.53 μg/l for furfural. Moreover, the procedure showed a good linearity and was applied to the analysis of wort samples taken from a wort boiling process in an industrial brewery.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.