Abstract

We used immunogold-silver staining to localize phosphoenolpyruvate carboxykinase in 10 microns cryosections of 4% paraformaldehyde perfusion-fixed normal male rat liver. The resolution and sensitivity of detection were improved by epipolarized light microscopy of 0.5 microns semi-thin plastic sections prepared from these pre-embedding immunogold-silver-enhanced 10-microns thick cryosections. Epipolarized light combined with transmitted light simultaneously demonstrated antigenic sites (visualized with epipolarized light illumination) and tissue morphology (revealed by transmitted light). To optimize the conditions for high resolution, an oil immersion objective lens (x 100) with adjustable iris diaphragm was used with different intensity settings for both light sources. Our observations indicate that if the intensity of the transmitted light is too high, the visibility of the gold-cored silver grains by epipolarized illumination is decreased; if the intensity of epipolarized light is too strong, haloes appear around the gold-cored silver particles. By adjusting the aperture in the objective lens and the neutral density filter in the transmitted light pathway to balance the intensities of transmitted and epipolarized light, an optimal image is obtained that shows the maximal number of antigenic sites and excellent morphology.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.