Abstract

The removal building heat load and electrical power consumption by air conditioning system are proportional to the outside conditions and solar radiation intensity. Building construction materials has substantial effects on the transmission heat through outer walls, ceiling and glazing windows. Good thermal isolation for buildings is important to reduce the transmitted heat and consumed power. The buildings models are constructed from common materials with 0 - 16 cm of thermal insulation thickness in the outer walls and ceilings, and double-layers glazing windows. The building heat loads were calculated for two types of walls and ceiling with and without thermal insulation. The cooling load temperature difference method, CLTD, was used to estimate the building heat load during a 24-hour each day throughout spring, summer, autumn and winter seasons. The annual cooling degree-day, CDD was used to estimate the optimal thermal insulation thickness and payback period with including the solar radiation effect on the outer walls surfaces. The average saved energy percentage in summer, spring, autumn and winter are 35.5%, 32.8%, 33.2% and 30.7% respectively, and average yearly saved energy is about of 33.5%. The optimal thermal insulation thickness was obtained between 7 - 12 cm and payback period of 20 - 30 month for some Egyptian Cities according to the Latitude and annual degree-days.

Highlights

  • IntroductionThe buildings heat load is proportional to the transmission heat through outside

  • The walls models are constructed from common materials with 0 - 16 cm of thermal insulation thickness in the outer walls and ceilings, and double-layers glazing windows

  • The optimal thermal insulation thickness and payback period are estimated for residential building from latitude of 16 ̊N to 32 ̊N

Read more

Summary

Introduction

The buildings heat load is proportional to the transmission heat through outside. The transmission heat load is added to the internal building heat load in summer season and subtracted from it in winter season. The thermal insulation is an effective tool to achieve the minimum heat transmission through walls. The transmission heat is a function of the thermal resistance of composite wall materials which are related to the thermal insulation thickness. The increasing of thermal insulation thickness will increase the investment cost, but reduce the electrical power consumption. The problem is how we can compromise between the investment of insulation cost and the running cost of electrical power consumption

Objectives
Methods
Findings
Conclusion