Abstract

AbstractSince the cure rate of injection molded thermosets is usually very sensitive to cavity surface temperature, spatial variations in these temperatures can lengthen the necessary cure time for the entire part and cause distortion and residual stress in the molded article. This problem is addressed in the present paper by combining an optimization algorithm with a quasi‐steady heat conduction analysis in the mold to determine the heating line positions and operating temperatures that minimize the spatial variation in cavity surface temperature. The method is applied to an example mold for a flat panel of uniform thickness, using two different gate locations. At a one‐minute cycle, the optimal designs for each gate location dramatically reduce the variation in cavity surface temperature compared with corresponding results using a conventional heating system. These results are made more significant by the fact that the optimal designs use considerably fewer heating lines. In spite of their simplicity, the optimal designs still have enough flexibility to adjust to a changing cycle without sacrificing uniformity in cavity surface temperature.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call