Abstract
Synchronous pulse-width modulation (PWM) based on precalculated and stored optimal pulse patterns could be a superior method for the control of high-power inverters operated at low switching frequency. The technique has rarely been applied in practice owing to its poor dynamic performance. A novel feedforward control technique eliminates this decisive drawback: the space vector of the machine currents is forced to track a precalculated optimal trajectory in the steady-state and under the transient operating conditions commanded by the drive control system. Undesired transients caused by the pulse-width modulator are avoided. Experimental results obtained from a 30 kW AC drive are presented.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.