Abstract

In this paper, we discuss optimal synchronization of local clocks using Global Positioning System (GPS) one-pulse-per-second (1PPS) timing signals. To eliminate sawtooth errors that are peculiar to the 1PPS signals and optimally steer the clock errors each M seconds, we propose the use of a ramp-predictive finite-impulse-response (FIR) filter that is known to be optimal for clock models on large averaging horizons. A low-pass filter is used to smooth the hold filter output between the optimally predicted points. A GPS-locked crystal clock has been investigated in detail in terms of the time interval error, Allan deviation, and precision time protocol (PTP) variance. A high-efficiency implementation of the proposed synchronization algorithm is experimentally demonstrated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.