Abstract
The present work implements Sine Cosine Algorithm (SCA) for obtaining optimal location and size of capacitor banks for addressing problems like voltage instability and line losses in radial distribution systems. By using power loss index (PLI) method, the buses that are more sensitive to the capacitor placement are identified and, thereafter, the location and size are optimized by using proposed SCA. The main objective of the system is considered as the minimization of the total cost. The algorithm is implemented on 33 bus and 69 bus test systems and the results obtained are compared with those yielded using other algorithms.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.