Abstract

A steel column that is reinforced by prestressed stays generally has an increased strength in axial compression. In the past, greater emphasis was placed on obtaining its higher critical buckling load. However, detailed knowledge of the post-buckling behaviour is important to ensure the safety and the efficiency of the structure. Although previous work revealed that the optimal design should be determined with the post-buckling response, the actual values of the optimal prestress had not been previously evaluated. The present work examines the issue of the true optimal prestress for stayed columns through proposed structural optimisation indicators involving both instability and material quantity measures. Non-linear finite-element analysis was performed to investigate the non-linear buckling behaviour, which gives values for these indicators. Through a comparison of these values, suggestions for the configurations for improving the structural efficiency are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.