Abstract

This paper introduced the principle of inner-furnace desulfurization system of CFB boilers by injecting limestone, and investigated the factors of the desulfurization efficiency. The desulfurization efficiency and stability of 480t/h CFB boilers manufactured by DongFang Boiler (Group) Co., Ltd were greatly increased by retrofitting the limestone injection position from dense region to the down secondary-air inlet of the back-wall. The improvement was achieved by increasing the oxygen concentration as well as optimizing the temperature of the reaction zone.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.