Abstract

The paper provides results from a hardware-in-the-loop experimental campaign on the operation of an air-source heat pump (HP) for heating a reference dwelling in Pisa, Italy. The system performances suffer from typical oversizing of heat emission devices and high water-supply temperature, resulting in HP inefficiencies, frequent on-off cycles, and relevant thermal losses on the hydronic loop. An experimentally validated HP model under different supply temperatures and part-load conditions is used to simulate the installation of a thermal storage between heat generator and emitters, in both series and parallel arrangements. Results relative to a typical residential apartment show that the presence of the thermal storage in series configuration ensures smoother heat pump operation and energy performance improvement. The number of daily on-off cycles can be reduced from 40 to 10, also saving one-third of electric energy with the same building loads. Preliminary guidelines are proposed for correctly sizing the tank in relation to the HP capacity and the average daily heating load of the building. A storage volume of about 70 L for each kilowatt of nominal heating capacity is suggested.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.