Abstract
AbstractThe purpose of the study was to collect data and evaluate an age‐based bulb replacement policy for projectors used in Technology‐enhanced classrooms in a university campus.The Office of Information Technology (OIT) had instituted a policy to replace bulbs in these projectors after either failure or 1800h of operation without failure. However, databases maintained by OIT included the time to bulb failure, the average number of times the bulbs were turned on and off per week, and the number of thermal events. Modeling the failure data with a Weibull proportional hazards model revealed that probability of bulb failure was a function of the number of hours a bulb was used and the frequency at which it was turned on and off. Combining this information with a cost model led to the recommendation for an improved condition‐based replacement policy. Copyright © 2009 John Wiley & Sons, Ltd.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.