Abstract
An experimental investigation into the effect of the displacement ratio of a heated horizontal pipeline within an atmospheric pressure air-filled, relatively cold, horizontal rectangular cavity was made. The optimal position of the pipeline to achieve maximum energy thrift occurred at a displacement ratio approximately equal to 0·7, i.e. in the upper region of the cavity. This result is of significance with respect to the reduction of distribution heat losses from underground district-heating pipelines.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.