Abstract

A survey of 53 university and community hospitals revealed that 73% of the institutions had no standard policy for the replacement of triple-lumen catheters (TLCs). Since the maintenance of a TLC in place for a prolonged period may lead to infectious complications, it appeared warranted that standards of management be developed. A decision-tree model was constructed for evaluating the optimal time for changing a TLC that would minimize infection. Cost estimates and health effects at three-, five-, and ten-day change intervals were considered for catheter insertion and complications resulting from such insertion. The results suggested that prophylactic catheter changes should occur no later than every five days, provided that there are no signs of infection. However, sensitivity analysis of several variables suggested that individual institutions should establish policy timing changes based upon careful interpretation of their own data. A model was developed to assist in determining the optimal time to change a TLC based upon such data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.