Abstract

With blunt and penetrating trauma to the chest, warfighters and civilians frequently suffer from punctured lung (pneumothorax) and/or bleeding into the pleural space (hemothorax). Optimal management of this condition requires the rapid placement of a chest tube to evacuate as much of the blood and air as possible. Incomplete drainage of blood leading to retained hemothorax may be the result of the final tube tip position not being in contact with the blood collections. To address this problem, we sought to develop a "steerable" chest tube that could be accurately placed or repositioned into a specific desired position in the pleural space to assure optimal drainage. An integrated infusion cannula was added for the instillation of anticoagulants to maintain tube patency, thrombolytics for clot lysis, and analgesics for pain control if required. A triple-lumen tube was designed to provide a channel for a pull-wire which was wound around an axle integrated into a small proximal handle and controlled by a ratcheted thumbwheel. Tension on the wire creates an arc on the tube that allows for positioning. In vitro testing focused on the relationship between the tension on the pull-wire and the resultant arc. Two adult cadavers and two anesthetized pigs were used to study the feasibility of accurate tube placement. After a brief training session, providers were asked to place tubes inferiorly along the diaphragm where blood was anticipated to accumulate or at the apex of the lung for pneumothorax. Success was determined with fluoroscopic images and was judged as a tube tip lying in the targeted position. The design was prototyped with an extruded polyvinyl chloride multilumen tube and a 3D printed tensioning handle. In vitro studies showed that one turn of the thumbwheel created 70° to 90° of arc of the tube. Cadaver and animal studies showed consistent success in the desired placement of the tube at or near the lateral diaphragm or in the apex. Attempts were also successful by surgical residents with minimal training. Initial preliminary studies on a novel steerable chest tube have demonstrated the ability to appropriately position the tube in a desired location. The addition of an extendable cannula will allow for safe clot lysis or maintained tube patency. Additional studies are planned to confirm the benefit of this device in preventing retained hemothorax.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call