Abstract

Objective[99mTc] d,l-hexamethyl-propyeneamine oxime (99mTc-HMPAO), a brain perfusion tracer, suffers significant underestimation of regional cerebral blood flow (rCBF). Lassen et al. developed their linearization algorithm to correct the influence of back-diffusion of the tracer, and proposed their parameter α as 1.5. Based on mathematical modeling and literature review, recently, a new α value of 0.5 has been proposed for Lassen’s correction algorithm for 99mTc-HMPAO, although correction using the old α value of 1.5 was confirmed to be sufficient. Inugami et al. reported that linearization correction gives a stable correlation coefficient over a wide range of α. Our hypotheses are that statistical noise is the source of the stable correlation coefficient presented by them and that the robustness of the correlation coefficient is the reason why many studies confirmed the value of α as 1.5.MethodsStatistical noise was added in silico to the count, whose relationship with flow was α = 0.5. Then, the count was corrected by Lassen’s linearization algorithm with a variety of α.ResultsThis study confirmed the hypothesis that smaller α values (strong correction) increase the noise at high flow values, leading to nominal increases in correlation coefficient as α decreases.ConclusionDespite this, adoption of the new, smaller α value of 0.5 would be more useful clinically in regaining the contrast between low-flow and high-flow areas of the brain.Electronic supplementary materialThe online version of this article (doi:10.1007/s12149-016-1073-z) contains supplementary material, which is available to authorized users.

Highlights

  • Objective [99mTc] D,L-hexamethyl-propyeneamine oxime (99mTc-HMPAO), a brain perfusion tracer, suffers significant underestimation of regional cerebral blood flow

  • Lassen et al developed their linearization algorithm to correct the influence of back-diffusion of the tracer, and proposed their parameter a as 1.5

  • Our hypotheses are that statistical noise is the source of the stable correlation coefficient presented by them and that the robustness of the correlation coefficient is the reason why many studies confirmed the value of a as 1.5

Read more

Summary

Introduction

Objective [99mTc] D,L-hexamethyl-propyeneamine oxime (99mTc-HMPAO), a brain perfusion tracer, suffers significant underestimation of regional cerebral blood flow (rCBF). Lassen et al developed their linearization algorithm to correct the influence of back-diffusion of the tracer, and proposed their parameter a as 1.5. Based on mathematical modeling and literature review, recently, a new a value of 0.5 has been proposed for Lassen’s correction algorithm for 99mTc-HMPAO, correction using the old a value of 1.5 was confirmed to be sufficient. Our hypotheses are that statistical noise is the source of the stable correlation coefficient presented by them and that the robustness of the correlation coefficient is the reason why many studies confirmed the value of a as 1.5. Methods Statistical noise was added in silico to the count, whose relationship with flow was a = 0.5. Division of Nuclear Medicine, Department of Radiology, National Center for Global Health and Medicine, 1-21-1 Toyama, Shinjuku-ku, Tokyo 162-8655, Japan.

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call