Abstract
The bandwidth for the recording of the orbicularis oculi blink reflex electromyogram (EMG) response is optimal when low-frequency artifacts, such as motion artifacts and cross-talk from other muscles, are maximally suppressed, whereas true EMG signal power is maximally retained. The optimal bandwidth was investigated for acoustic, electrocutaneous, and photic blink reflexes. Reflexes were recorded with varying bandwidth and interelectrode distances of 12 and 36 mm. Power spectra of the EMG signals were calculated and compared with a theoretical spectrum of the uncontaminated EMG signal. For both electrode distances, the optimal bandwidth was on the average 28-500 Hz for acoustic and electrocutaneous blink reflexes and 12-500 Hz for photic blinks. Using photic stimuli, however, a high-pass filter frequency larger than 12 Hz (probably at least 30 Hz) in combination with occlusion of the eye will be necessary to avoid influences of retinal potentials. Given the optimal bandwidth, a larger electrode spacing may be expected to moderately improve the detectability of small blinks in all stimulus conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Psychophysiology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.