Abstract
Optimal design of sensitive structure in gas pendulum tilt sensor was discussed. Using ANSYS software, fluid fields produced by heat source of the sensor in center were simulated. According simulated temperature field which is the key sensitive factor of the tilt sensor, optimal design of sensitive structure was discussed further. The results show that sensitivity of sensor is better when the distance between sensor wire and heat source is 0.2 R or 0.3R (R is radius of chamber). In respect to vertical place, experiment and theory show sensor has better sensitivity and linearity when installing angle is 60 ̊ while the horizontal distance between sensor wire and heat source is 0.3R.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.