Abstract

Characteristics of a tuned magnetic fluid damper are examined. The optimal depth of amagnetic fluid in a cylindrical container is calculated using a linear analysis of amagnetic fluid sloshing. In order to avoid swirling in lower depth fluids, severalexperiments using greater fluid depths are carried out and a good damping range isobtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call