Abstract

This paper optimizes the design of a novel large-span cable-supported steel–concrete composite floor system in a simply supported single-span, single-strut configuration, aiming for cost-effective solutions and minimal steel consumption. The optimization considers various cross-sectional dimensions, adhering to building standards and engineering practices, and is based on a non-linear programming (NLP) algorithm. Parameters of live loads ranging from 2 to 10 kN/m2 and spans from 20 to 100 m are considered. The optimization results show that cable-supported composite floors with a single strut exhibit robust economic feasibility for spans of less than 80 m and live loads under 8 kN/m2. Compared to conventional composite floors with welded I-beams, the cable-supported system offers more cost-effective cross-sections and reduces steel consumption. The savings in economically equivalent steel consumption range from 20% to 60%. Discussion on the area ratio of cables to steel beam in the optimal cross-section reveals that the secondary load-bearing system (i.e., bending of the main beam with an effective span length of L/2) may require more steel in cases of ultra-large spans. Therefore, the economical efficiency of cable-supported composite beams with multiple struts and smaller effective span lengths warrants further exploration in future studies.