This paper presents the application of a Medium-Frequency (MF) Transformer design methodology applied to a 400kVA transformer intended for railway traction multi-voltage applications. First, a full-scale prototype operating at a moderate frequency (<1kHz), based on a silicon-steel transformer and a Dual Active Bridge (DAB) has been developed and experimentally verified. Then, in order to reduce the volume and weight of the system, a second full-scale prototype has been designed based on a higher operation frequency (>5kHz), a nanocrystalline transformer and a Series Resonant Converter (SRC), which has evolved towards a LLC Resonant Converter. A major volume and weight reduction (more than 85%) has been achieved between both designed transformers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.