Abstract
The purpose of this paper is to propose an efficient and systematic procedure for finding the optimal damper placement to minimize the sum of amplitudes of the transfer functions evaluated at the undamped fundamental natural frequency of a structural system subject to a constraint on the sum of the damping coefficients of added dampers. Optimality criteria are derived and the optimal damper placement is determined based upon those criteria without any indefinite iterative operation. The present procedure can be applied to any structural system so far as it can be modelled with finite-element systems. The present procedure also enables one to treat structural systems with an arbitrary damping system (for example, proportional or non-proportional) in a unified manner. Due to employment of a general dynamical property, i.e. the amplitude of a transfer function, the results are general and are not influenced by characteristics of input motions. © 1997 John Wiley & Sons, Ltd.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.