Abstract

This paper discusses optimal configuring and commissioning of laboratory system that consists of FC-302 high performance frequency converter and induction motor. In the beginning frequency converter control of induction motor is explained. Furthermore, the measurements of slip compensation parameter change influence on motor speed and motor load dependence are performed, as well as measurements of power factor correction attained by frequency converter. It is possible to compensate slip completely, so that motor speed is constant, regardless of motor load, which provides optimal control. Frequency converter partially compensates power factor of converter - motor system with capacitors of passive filter.