Abstract

We report on the application of an optical beam to redirect sheathed micro-fluidic flow without direct interaction with the sample. The hydrodynamic properties of the sheath are locally modified due to optical heating, resulting in a spatial shift of the sample flow. We characterize this technique for a range of flow rates and demonstrate up to 100 μm shift at peak flow velocities of 19 mm/s. We also model the temperature and viscosity changes, as well as the flow velocity profiles for a two-fluid flow with different viscosities. The calculated shifts in the flow profile correspond well with the measured shifts.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.