Abstract

Optical properties of the rat head tissues (brain cortex, cranial bone and scalp skin) are assessed, aiming at transcranial light applications such as optical imaging and phototherapy. The spectral measurements are carried out over the wide spectral range of 350 to 2800 nm, involving visible, near-infrared (NIR) and short-wave infrared (SWIR) regions. Four tissue transparency windows are considered: ~700 to 1000 nm (NIR-I), ~1000 to 1350 nm (NIR-II), ~1550 to 1870 nm (NIR-III or SWIR) and ~2100 to 2300 nm (SWIR-II). The values of attenuation coefficient and total attenuation length are determined for all windows and tissue types. The spectra indicate transmittance peaks in NIR, NIR-II and SWIR-II, with maximum tissue permeability for SWIR light. The use of SWIR-II window for the transcranial light applications is substantiated. Furthermore, absorbance of the head tissues is investigated in details, by defining and describing the characteristic absorption peaks in NIR-SWIR.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.