Abstract

PurposeThis paper sets out to give an overview about state‐of‐the‐art optical tomographic image reconstruction algorithms that are based on the equation of radiative transfer (ERT).Design/methodology/approachAn objective function, which describes the discrepancy between measured and numerically predicted light intensity data on the tissue surface, is iteratively minimized to find the unknown spatial distribution of the optical parameters or sources. At each iteration step, the predicted partial current is calculated by a forward model for light propagation based on the ERT. The equation of radiative is solved with either finite difference or finite volume methods.FindingsTomographic reconstruction algorithms based on the ERT accurately recover the spatial distribution of optical tissue properties and light sources in biological tissue. These tissues either can have small geometries/large absorption coefficients, or can contain void‐like inclusions.Originality/valueThese image reconstruction methods can be employed in small animal imaging for monitoring blood oxygenation, in imaging of tumor growth, in molecular imaging of fluorescent and bioluminescent probes, in imaging of human finger joints for early diagnosis of rheumatoid arthritis, and in functional brain imaging.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call