Abstract

The use of optical time-domain reflectometry (OTDR) on long-span fiber transmission systems containing in-line optical amplifiers is discussed. Having identified the specific requirements for OTDR equipment, measurements were carried out on systems of up to 300 km in length, containing three semiconductor laser amplifiers. The results demonstrate that OTDR can be used not only for fault location on fiber links several hundred kilometers in length but also as an alternative to standard system supervisory techniques, thus providing the potential for minimizing the hardware in the optical amplifier stages of future long-span fiber optic transmission systems.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.