Abstract

Although nonlinear microscopy and fast (approximately 1 ms) membrane potential (Vm) recording have proven valuable for neuroscience applications, their potentially powerful combination has not yet been shown for studies of Vm activity deep in intact tissue. We show that laser illumination of neurons in acute rat brain slices intracellularly filled with FM4-64 dye generates an intense second-harmonic generation (SHG) signal from somatic and dendritic plasma membranes with high contrast >125 microm below the slice surface. The SHG signal provides a linear response to DeltaVm of approximately 7.5%/100 mV. By averaging repeated line scans (approximately 50), we show the ability to record action potentials (APs) optically with a signal-to-noise ratio (S/N) of approximately 7-8. We also show recording of fast Vm steps from the dendritic arbor at depths inaccessible with previous methods. The high membrane contrast and linear response of SHG to DeltaVm provides the advantage that signal changes are not degraded by background and can be directly quantified in terms of DeltaVm. Experimental comparison of SHG and two-photon fluorescence Vm recording with the best known probes for each showed that the SHG technique is superior for Vm recording in brain slice applications, with FM4-64 as the best tested SHG Vm probe.