Abstract

Optical phase imaging has many applications, it allows to image transparent objects like cells without staining, which is a huge benefit in biology, and also allows to measure the phase from reflecting objects to determine their topography. Furthermore, there are many applications in life science, material science, healthcare and industry for optical phase imaging. There exist different methods to image phases, phase contrast microscopy converts the phase information into amplitude contrast, but is difficult to interpret quantitatively, quantitative phase microscopy (QPM) on the other hand tries to determine the phase information quantitatively. Several full‐field QPM methods exist, they can be divided in off‐axis approaches and inline approaches. Off‐axis approaches need a special microscope due to the reference beam and suffer from the high coherence of the illumination resulting in phase noise. Inline approaches could be divided in phase‐shifting methods, common‐path methods, digital inline holography, ptychography, Shack–Hartmann wave front sensors and focal series reconstruction, e.g. from the transport of intensity equation (TIE). Some of these approaches need special equipment, like laser illumination, gratings or spatial light modulators, which makes them expensive or introduces artefacts from the experimental setup or from the reconstruction algorithm. Focal series reconstruction has the advantage, that it only needs a standard optical microscope plus a computer and no additional equipment, this makes quantitative phase imaging from focal series reconstruction both an easy and a low‐cost method. Figs. 1 & 2 present results obtained by our current approach to optical quantitative phase imaging, where we use focal series reconstruction with partially coherent illumination (a green LED source). The images were aquired using a Zeiss Axiovert 200M microscope and a pco edge sCMOS camera by varying the object height (z = 0µm is the focal plane). We apply our flux‐preserving iterative reconstruction algorithm [1] and combine it with a TIE‐like approach [2]. It aligns the images during reconstruction and applies gradient‐flipping regularization [3]. This full‐resolution inline holography (FRIH) algorithm [2] was originally developed for electron microscopy, but here we apply it to optical microscopy. We will discuss the validity of the reconstruction, especially with respect to artefacts and present the algorithm and the results in more detail.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.