Background. To evaluate the optical quality and related factors in patients with ocular hypertension (OHT). Methods. This was a prospective case-control study. A total of 12 eyes with OHT and 20 control eyes underwent testing with Optical Quality Analysis System II (OQAS II) to evaluate the modulation transfer function cut off frequency (MTF cutoff), the Strehl 2D ratio (SR), objective scatter index (OSI), tear-film mean OSI (TFOSI), and the OQAS values (OV100%,OV20%, and OV9%). Results. The optical quality of patients with OHT declined, with lower MTF cutoff (OHT 36.86 ± 7.11 cpd , controls 48.50 ± 4.04 cpd, t = −4.60, P < 0.05), lower SR (OHT 0.22 ± 0.04, controls 0.27 ± 0.05, t = −2.72, P < 0.05), lower OV100% (OHT 1.26 ± 0.25, controls 1.61 ± 0.14, t = −4.03, P < 0.05), lower OV20% (OHT 1.27 ± 0.27, controls 1.72 ± 0.20, t = −4.00, P < 0.05), and lower OV9% (OHT 1.30 ± 0.25, controls 1.69 ± 0.32, t = −2.28, P < 0.05). There were not any statistically significant differences in OSI and TFOSI. The MTF cutoff in patients with OHT was correlated significantly with age (r = −0.59, P < 0.05). Conclusions. Optical quality of patients with OHT is reduced, with lower MTF cutoff, SR, OV100%, OV20%, and OV9%. MTF cutoff is negatively related to age.

Highlights

  • To evaluate the optical quality and related factors in patients with ocular hypertension (OHT)

  • A total of 12 eyes with OHT and 20 control eyes underwent testing with Optical Quality Analysis System II (OQAS II) to evaluate the modulation transfer function cut off frequency (MTF cutoff), the Strehl 2D ratio (SR), objective scatter index (OSI), tear-film mean OSI (TFOSI), and the OQAS values (OV100%,OV20%, and OV9%)

  • intraocular pressure (IOP) and central corneal thickness (CCT) were found to be positively correlated by several studies [6, 7], but so far, there is no accurate algorithm for correction

Read more

Summary

Introduction

To evaluate the optical quality and related factors in patients with ocular hypertension (OHT). Optical quality of patients with OHT is reduced, with lower MTF cutoff, SR, OV100%, OV20%, and OV9%. The Ocular Hypertension Treatment Study (OHTS) demonstrated that the cumulative incidence of POAG was 9.5% in the patients with OHT [3]. Our study analyzed the optical quality with OQAS II (Visiometrics SL, Spain), which provides parameters such as MTF cutoff, SR, OSI, TFOSI, and OVs. In the meantime, we register the general information of the patients with OHT

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call