Abstract

In order to improve the safety of nuclear power plant, loss-of-coolant accident experiments are implemented in research reactor. In this framework, we develop an optical pyrometry device to measure surface temperature (700-1200°C) of Zircaloy cladding without contact. The whole set-up of the simplified device (under air, without radiation) and the measurement procedure including data treatment based on bichromatic pyrometry are presented, as well as results for various temperature levels. Temperature retrieval based on the hypothesis of emissivity ratio equal to a constant, is scanned over a large wavelength range. A rather constant surface temperature is obtained on the spectral range of measurement, confirming the relevancy of emissivity hypothesis. Differences between this non-contact temperature measurement and a complementary thermocouple temperature measurement are also discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.