Abstract

The optical performances of the spectrometer assembly for the Ultraviolet Coronagraph Spectrometer of the Solar and Heliospheric Observatory mission have been tested. The flight unit of the spectrometer assembly, consisting of the structure equipped with the entrance slits assembly, the grating drive mechanisms mounting two toroidal gratings, and the photon-counting detectors, has been integrated and aligned; also the flight unit of the White Light Channel has been integrated and aligned in the spectrometer assembly. Tests with both visible and UV radiation have been performed. Aberration and stray-light measurements have shown that the instrument performs satisfactorily, almost in compliance with the scientific requirements; also some measurements of the polarimeter modulation curve and the relative error have shown performances within the specified requirements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.