Abstract

The wetness fraction of steam causes dangerous erosion of turbine blades and other components, and decreases efficiency of stages. The instrumentation of wet steam has, therefore, attracted growing interest from the point of safety and economical operation of power stations. Based on the light scattering technique, a method is presented that is capable of measuring the wetness fraction of steam, the mean water droplet diameter as well as their full size distribution. An optical probe has been constructed that can be used in the turbines in operation. Its main characteristic and features are discussed in this paper. Experimental results in a 200 MW condensing steam turbine are also given.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.