Abstract

In photovoltaics (PV), sun simulators are used to reproduce outdoor conditions in a lab environment such as irradiance level, light uniformity and spectral distribution. Concentrator (C)PV applications additionally require the sun simulators to provide rays with an angular distribution similar to that of the sun rays. However, different factors in CPV sun simulator setups make it difficult to achieve the perfect sun like angular distribution. This is mainly caused by the unavailability of appropriate light sources. Therefore, we investigated in this work, to which deviations such a non-ideal light source can lead and which impact is expected at the measurement of a CPV module. For this, two ray tracing models are presented - one for the simulation of natural sunrays, another one for the simulation of sun simulator conditions. The models are validated based on measurements and subsequently used to simulate the impact on a typical CPV module with silicone-on-glass Fresnel lenses. Here, significant deviations to outdoor conditions are found.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.