Abstract

Radioisotopes production for PET radiopharmaceuticals is performed using cyclotrons resulting in radio activation of different cyclotron components. It is thus necessary to measure the level of radiation exposure and, if possible, to image the areas where most of the radiations are emitted in particular during maintenance or decommissioning procedures. In this work we present a novel optical imaging approach using Cerenkov luminescence imaging (CLI) and radioluminescence imaging (RLI). CLI was performed by placing a glass Cerenkov radiator on a target window (Havar foils) and RLI data were obtained by covering the Havar foils with an intensifying screen. CLI or RLI were acquired using a small animal optical imaging system used in bioluminescence mode without the use of any optical filters. The analysis of the normalized radiance line profiles of both CLI and RLI images showed a similar pattern, however the absolute radiance of the RLI signal is several order of magnitude higher with respect to CLI. We conclude that optical imaging with CLI and RLI can be considered a novel method to detect and image activation areas in irradiated samples from a medical cyclotron.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.