Abstract

Range resolved interferometry (RRI) applied to the interrogation of an extrinsic Fabry–Perot based pressure sensor in laboratory and wind tunnel environments is presented. A simple, compact sensor head design was fabricated and subsequently characterised using RRI, which was shown to have a sensitivity of 1.627 rad Pa−1 with a noise standard deviation of 9 Pa over a data rate of 1.5 kHz. When installed in a high-lift wing for surface pressure evaluation during wind tunnel testing, the approach outlined here was able to perform as well as a conventionally employed commercial device for relative static pressure measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.