Abstract

To detect the pollution level of insulators in operation, based on light energy loss theory of medium optical wave guide and mathematical modeling of least squares supporting vector machine, by a lot of contrast tests, this paper designed and developed monitoring terminal of optical sensor. Collecting live temperature, humidity luminous flux attenuation etc. and sending the collected data to data monitoring centre through GSM data communication module, the workstation of data monitoring centre could calculate to get equivalent salt deposit density (ESDD) using mathematical model, so that insulators pollution level can be detected on-line automatically and continuously.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.