Abstract
An optical fiber Fabry–Perot interferometer (FPI) based on an air cavity with a microchannel is proposed and demonstrated for gas pressure measurement. The inner air cavity is fabricated by fusion splicing a single-mode fiber (SMF) with a microhole at the end facet to another section of SMF, then creating a microchannel to vertically cross the air cavity to allow gas to flow in. As the air cavity is cascaded to a short section of SMF, a three-beam interference pattern is produced, which shifts with the gas pressure variation in the inner air cavity due to the refractive index change of the gas. In order to compensate the temperature effect, the multiple-dip tracing technique and the Fourier band pass filtering (FBPF) method are used simultaneously for gas pressure and temperature measurement. It is also found that by using the FBPF method, the gas pressure sensitivity does not depend on the resonant peaks/dips selected in the filtered spectrum of the device. The proposed device has a robust tip structure, miniature size, and high sensitivity (∼4.028 nm/MPa) and is easy to fabricate, which makes it attractive for highly sensitive and precise gas pressure measurement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.