Abstract

An assessment for the safe use of electrical equipment in explosive atmospheres can be performed with the aid of a spark test apparatus. Therefore, an anodic tungsten wire with 200 µm diameter is moved along the surface of a rotating cadmium disc (cathode). The explosion chamber enclosing the electrodes is filled with a highly explosive mixture of hydrogen and air. Depending on surface topology and relative movement of the contact pair, discharges occur randomly. A model contact device is used to investigate the plasma properties and the discharge characteristics near the thermo-chemical ignition threshold of the explosive atmosphere that typically occur at voltages around 30V and currents around 30mA.Spectroscopic investigations reveal that the emission of the discharges is dominated by atomic lines of cadmium, which allow the determination of distribution temperatures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.