Abstract

Room temperature optical constants of plastic materials have been measured over the 50-350-cm(-1) spectral range. The materials reported include high density polyethylene, TPX, Aclar, Kapton, Surlyn, and Mylar. All except TPX are available in sheet form and exhibit birefringence as a consequence of stretching during the manufacturing process. Only the average of the two sets of optical constants is reported for each material. The refractive index was calculated from the channeled spectrum as observed in reflection from the sample, while the absorption coefficient was determined, in all cases but polyethylene, from a transmission measurement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.